Mitsubishi MELSEC & FREQROL End-of-Life / Migration Reference

Series-level lifecycle status with Mitsubishi's full published schedule where given — transition to make-to-order production, order acceptance (last-order date), production discontinuation, and repair-support end — for legacy Mitsubishi Electric automation: MELSEC A/QnA, MELSEC-Q legacy and Universal CPUs, MELSEC-F FX1/FX2N/FX3 generations, FREQROL inverters, MELSERVO MR-J2S/MR-J3, GOT900/GOT1000 HMI, and MELSOFT software (GX Developer, GT Designer2).

One record is time-critical: the MELSEC-Q Universal QnUD(H) CPUs (bulletin FA-A-0418-A) — order acceptance closed September 30, 2026; production discontinuation October 30, 2026; repair support until October 31, 2033. Anyone still running Q03UD–Q26UD(H) CPUs who wants factory spares has missed the order window; the published paths are the Highspeed Universal QnUDVCPU (in-platform) or MELSEC iQ-R. Other families sit at the opposite end of the ladder — the MELSEC-Q C Controller modules are not discontinued until 2030 — so knowing where a family sits on Mitsubishi's published schedule is what maintenance and modernization planning for the installed MELSEC base depends on.

Honesty notes: FX3S is still ACTIVE — Mitsubishi publishes no discontinuation notice for it, and the dataset carries it as an Active status record rather than falsely retiring it. FX3U/FX3UC are NOT yet EOL — orderable until March 31, 2028 (production ends September 30, 2028, repair support to 2035). And the published replacement for the FR-E500 is the FR-E700, not FR-E800 — recorded as Mitsubishi published it.

Verification standard: official Mitsubishi Electric sources first (the mitsubishielectric.com global FA document library — technical bulletins FA-A / FAM-A / HIME-T-P / GOT-A and sales notices — plus Mitsubishi Electric Automation US and Mitsubishi Electric Europe). Lifecycle dates are reproduced exactly as published and left blank where Mitsubishi published none — no dates, part numbers, or successors are inferred. Only 1 of the 30 records rests on a distributor source because Mitsubishi's own original was not readable in this pass; it is tagged [distributor-sourced] and is lower-confidence. A few Mitsubishi-authored documents were read via third-party mirrors, noted per record in the full file.

Free sample — 5 of 30 records

Product FamilyCatalog/SeriesLifecycle StatusDiscontinuation or milestone dateRecommended Replacement / Migration Path
MELSEC-A / QnA programmable controllers (large type)A/QnA large-type CPU, I/O, special function and data link modulesProduction discontinued (Mitsubishi MELSEC-A/QnA Series Transition Guide, L08077E)CPU, I/O, special function and data link modules: production discontinued end of September 2006; MELSECNET/MINI-S3 master module: end of September 2008; MELSECNET/10 network module: end of September 2014 (bulletin FA-A-0141)MELSEC-Q series per the transition guide; Mitsubishi's current published direction for the MELSEC-A series is MELSEC iQ-R (see the A61PN/A61RP record, FA-A-0365-A)
MELSEC-Q Universal model QCPU (selected models)Q03UDCPU, Q03UDECPU, Q04UDHCPU, Q04UDEHCPU, Q06UDHCPU, Q06UDEHCPU, Q10UDHCPU, Q10UDEHCPU, Q13UDHCPU, Q13UDEHCPU, Q20UDHCPU, Q20UDEHCPU, Q26UDHCPU, Q26UDEHCPUProduction discontinuation announced (Technical Bulletin FA-A-0418-A) — order acceptance closed September 30, 2026Order acceptance: until September 30, 2026; production discontinuation: October 30, 2026; repair support: until October 31, 2033Highspeed Universal model QCPU (Q03UD→Q03UDVCPU, Q04UDH→Q04UDVCPU, Q06UDH→Q06UDVCPU, Q10UDH/Q13UDH→Q13UDVCPU, Q20UDH/Q26UDH→Q26UDVCPU) or MELSEC iQ-R CPU (→R04CPU / R08CPU / R16CPU / R32CPU per the bulletin's replacement table)
MELSEC-F compact PLCs (FX3U / FX3UC and extension models)FX3U / FX3UC main units; remaining FX2N / FX2NC extension units; FX3U/FX3UC special function modules, boards, adapters and cablesProduction discontinuation announced (Technical Bulletin FAM-A-0116-B)Start of make-to-order production: January 1, 2028; order acceptance: until March 31, 2028; production discontinuation: September 30, 2028; repair support: until September 30, 2035MELSEC iQ-F series: FX3U→FX5U or FX5UJ; FX3UC→FX5UC; extension/special modules→FX5 equivalents model-for-model in the bulletin (e.g. FX3U-4AD→FX5-4AD, FX3U-16CCL-M→FX5-CCL-MS, FX2N-16EX→FX5-CNV-IF + FX5-C16EX/D)
FREQROL invertersFR-A500 / FR-A500LProduction terminated (Mitsubishi "Proposal for Upgrading and Introduction" — production termination schedule table)Production termination: April 2007; repairs and spare parts until April 2014FR-A800
GOT HMI (GOT1000 series)GT16 main units and option unitsProduction discontinued — "production of all GOT1000 series models and option units have been discontinued" (Technical Bulletin GOT-A-0095-Q)Transition to make-to-order: September 30, 2018; order acceptance: through August 31, 2019; production discontinuation: September 30, 2019; repair acceptance: CCFL-backlight models through December 31, 2021, LED-backlight models through September 30, 2026GOT2000 — GT27 / GT25, model-for-model in the bulletin; the bulletin specifies the minimum GT Designer3 (GT Works3) version for each replacement model

Sample rows are copied verbatim from the paid dataset file, including its blank dates where Mitsubishi published none.

Full dataset — paid

Full file: all 30 series-level records (14 controllers, 7 inverters, 2 servo amplifiers, 5 HMI, 2 software), each with migration conditions and source URLs, plus per-family migration notes and a coverage-gaps section listing families checked and deliberately excluded for lack of a verifiable record. Clean Markdown, compiled 2026-10-21.

Price: 0.10 USDC · Protocol: HTTP 402 (x402, Base) · GET /data/mitsubishi-automation-eol-migration-v1.md → 402 → pay → 200

Get the full Mitsubishi Electric Automation EOL & Migration Cross-Reference v1 (0.10 USDC)

Catalogue for crawlers and agents: /llms.txt · Full catalogue: /llms-full.txt · AI Data Refinery home


Facts compiled from public OEM lifecycle sources; not affiliated with or endorsed by Mitsubishi Electric. Trademarks belong to their owners. This is a migration-planning reference, not engineering sign-off. Mitsubishi issues discontinuation schedules per model group, so series-level records must not be read as per-catalog-number dates — verify production-critical selections against Mitsubishi's FA product search and technical-bulletin library for the exact model before acting.